Feature(may vary by option.)

●Pulse signal range: 1~10000Hz frequency pulse signal,
●Pulse Duty Cycle Range: 0-100.0% Duty Cycle
●Pulse Signal Amplitude: 5VDC, Max. 5V, fixed output amplitude
●Phase adjustment range: 0 - 360 degrees (phase difference between 1st and 2nd channel)
●Frequency measurement range: 1 - 1000 kHz

[1-1000KHz]





Description

Adjustable 2 Channel 1Hz to 100kHz Frequency Pulse Signal Generator Phase Adjustable Servo Duty Cycle Output Frequency Meter Module

Technical Parameters

Pulse signal range: 1~10000Hz frequency pulse signal,

Pulse Duty Cycle Range: 0-100.0% Duty Cycle

Pulse Signal Amplitude: 5VDC, Max. 5V, fixed output amplitude.

Phase adjustment range: 0 - 360 degrees (phase difference between 1st and 2nd channel)

Frequency measurement range: 1 - 1000 kHz

Frequency measurement accuracy: 1 Hz

Frequency measurement bolt range: ±0.7-10VD, direct coupling

Servo signal frequency: 100Hz

Servo signal pulse width: 500~2500US

Operating Power: 7-12 VDC

Operating current: <;50mA

Dimensions (LXWXH): 2.2 x 1.8 x 0.8 inches (57 x 45 x 20

Wiring Terminal Description

VDD: Power positive (7-12VDC)

GND: Power Supply Negative

Fin: Frequency signal measurement input.

P2: Second channel pulse signal output

P1: First channel pulse signal output

GND: Power Supply Negative

Button operation

Fun: Choose or set data control mode(Long press to save settings).
Left: Auto add key
Log Hog: Auto-Subtraction Key

User Manual

Screen interface and operation procedures
Set 6.1 pulse signal frequency

LCD.Screen display interface
First Line: "1 Frequency:
Second line: "* 1 1000Hz"

6.2 Pulse Signal Duty Cycle

LCD.Screen display interface
First Line: "2. Duty Cycle"
2nd row: "* 0.1 50.0%"
6. Set the phase difference between the third and the second channel (1st channel as standard)

LCD.Screen display interface
1st Line: "3. Phase"
Second line: "* 10c"

6.4 output servo pulse signal

LCD.Screen display interface
1st Row: "4. Servo Control"
Second line: "* 1 500US"

6.5 frequency signal measurement

LCD.Screen display interface
Line 1: "5.frequency.1MHZ "
Second Row: "Off 0.Hz "

Button operation
Left: Set the frequency signal measurement range (Auto add key)

Frequency pulse servo signal generator test

2 channel 1kHz square wave signal output
500US Servo Signal Output

Pulse frequency generator package

1 unit x Pulse frequency signal generator module

1 x Professional User Manual