Model: LS102480GPU LS2024100GPL
Nominal system voltage 12/24VDC auto
Rated charging current: 10 A, 20 A.
Maximum voltage: 50 V, 50 V.
Max.Output Power: 40W / 12V; 80W / 24V 50W / 12V 100W 124V
Maximum Output: 4 A, 4 A.
Max Output Voltage: Min.VBAT -0 5V Min VBAT-1V
Battery Operated Seal (default) IGel / Flooded
Equalize Rechargeable Battery Seal: 14 6 V, Water Infusion: 14.8 V, User: 9 - 17 V.
Boost Charging Voltage "Gel:14 2V,Seal:14.4V,Submersion:14.6V,User 9-17V
Floor Charging Voltage Gel/Sealing/Intrusion: 13.8 V, User 9-17 V
Low voltage reconnect voltage gel/sealed/submersion:12.6V; User:9-17V
Low voltage cut-off voltage gel/seadid/flood: 11.1V; User: 9-17V
Maximum output efficiency 96%
Output Current Control Accuracy: 50mA
IR s6m communication distance
Self-consumption: 16 mA (12 V) s20 mA: 24 V)
Efficient compensation of -3mV/C/2V by temperature compensation
Overall Dimension:10 7x68x20mm 108.5x88x25.6mm
Powercable PV / BAT 14AWG (2 5mm? Load: 18 AWG (1O0 mm2) Load: 18 AWG (1 mm) PV BAT 14 AWG (4 mm2)
Netweight 0.25kg 0.39kg
Enclosure IP68 (1.5m, 72h)
Working Environment Temperature: -35°C to +55°C
"Technical data of 12V systems at 25°C twice at 24V system rate