Feature

●1. The gloss meter can be measured in real time, no key operation is required, and the measurement is fast and accurate, so you can use it with confidence
●2. The gloss meter has ambient temperature compensation, the value is stable and can be calibrated for a long time
●3. USB transmission, support dedicated operating software, you can operate online on your computer to complete test report
●4. The gothmeter adopts ergonomic design, beautiful appearance, comfortable grip, and QC decision function, which can quickly detect the contents inside
●5. Built-in rechargeable lithium battery, very low power consumption, can be used continuously for over 32 hours on a single charge


Description

LS195 Glossometer Intelligent Stone Metal Luster Industrial Glossy Testing Equipment Specifications: Item Type: Glossometer Model: LS195 Material: ABS Battery: 1 x Rechargeable Lithium Battery 3.7V 650mAh (Battery Included) Purpose: Sampling and Glossy Measurement Comparison Applications: Paint, Coating, Ink, Plastic, Paper, Ceramic Tile, Ceramic, Masonry, Metal, Electroplating Layer Measuring Angle: 60 Measuring Spot: Approx. 9 x 15mm / Approx. 0.4 x 0 Minimum size of .6 inch test object: about 20 x 10mm / 0.8 x 0.4 inch Measuring range: 0-200GU Resolution: 0.1GU Reproductivity: 0-100GU: 0.2GU100-200GU: 0.2% Reproductivity: 0GU: 0.5GU100-20GU: Read. 0.5% error : 0.1GU display error: 0-100GU: 1.5GU100-200GU: 1.5% Readable System Language: Chinese, English Display: 240 x 128 Dot LCD Charging Interface: USB (Type C) Data Interface: USB Operating Temperature Range: 10 ~ 45, 0 ~ 85% RH (No condensation) Storage Temperature: -1 0-60, 0-85%RH (no condensation) How to use: 1. Power on/off power: In the OFF state, short press the device button to turn on Shutdown: Long press the device button to shut down if no operation is more than 3 minutes, the device will automatically shut down Machine 2. In the parameter setting shutdown state, press the device button for 3 seconds to enter parameter setting mode A. Language Short press the button to china. Choose words or English, then long press the 3S button to complete setting, enter the following settings: B. Short press the mode selection button to choose normal mode or QC mode, then long press the 3S button to complete setting, finish setting and enter calibration interface 3. Put the device calibration device on the standard board to turn on the opportunity to enter the calibration interface User can perform calibration operation according to calibration prompt. Measurement interface when correct If the device is not placed on a standard board, the calibration is skipped, and the measurement interface is directly entered into the measurement interface If you see a message that indicates the calibration fails to fail, the standard board is dirty Clean with a dedicated lens cloth, and buckle the host to the base The host is not close to the standard board, then buckle it back to the base once again if the ambient temperature changes greatly the temperature and ambient temperature will become close. Lens in device test port After checking the base board there is no condensation on the base and resume the measurement. If the light source fades will not be used properly, you will need to return it to the factory for inspection or repairing. If the device shows "failed calibration", you can press the button to skip the calibration. Package List: 1 x Glossometer (batteries included) 1 x U disk 1 x D.