Feature

●The analog dynamometer is small size, high precision, easy to operate, and easy to carry. Both Newton and Kilogram units can be displayed at the same time. The Peak/Track knob can switch between peak and continuous load test
●It is an excellent product to replace the old dynamometer, widely used in industry testing of electronics, hardware, auto parts, lighters, ignition systems, light industry, machinery, textiles and more. Load Test Insert or Pull or Push Tensile Force and Destructive Test. Please read the instructions carefully before using this device
●NK, NLB and ALB series are small and high precision analog dynamometers. They are easy to operate and easy to install
●It is widely used in rubber and plastic, light industrial industry, textile, building doors, windows, composites, wires, cables, automotive parts, generators, and scientific research units for push-pull insertion and destructive experiments
●Easy to operate, can install a variety of test benches and equipment. Peak hold function and continuity


Description

Both units are displayed simultaneously without unit conversion.
NK Series: Newton and Kilogram Double Unit
NLB Series: Newton and Pound Double Unit
ALB: 2 lbs and kilograms
Pointer display, convenient reading, high precision
PRE-TEST PRE-TEST:
Select the appropriate connector clamp and install it to the gauge before testing.
(1) Tension Test
Select cable clamp and attach to the center rod marked "pull"
(2) Thrust Test
Select the push clip and install on the center rod labeled "Push".
(3) Use the extension stick
If you cannot touch the test object, use the extension rod to install the clamp.
Note:
During testing, the measured object and gauge must be the same straight line, or you cant test the correct load values.
(4) Make sure you change the way you operate the knob.
(a)Change [peak]
Lightly press the knob on the switch and turn to the left at the same time as the "□" mark is in the [TRACK] position.
(b) [TRACK] [Peak] Changes
Turn the knob to the right, the knob pops up, and the mark "□" is in the [TRACK] position.
(c) Precautions after testing
After testing is completed, change the mark "□" and place it in the [Peak] position. Placing the replacement knob in the [track] position for a long time, the internal life will be shortened.
(5) Indicator Plate Adjustment
(a) Please check if the dial matches [O]. Otherwise, please turn the adjustable ring on the dial. The dial can be used to rotate and the pointer is aligned with [o].
(b) When the machine is positioned vertically, the needle will tilt even if the jig is installed, especially if it is not loaded. This is the cause of the weight of the machine and jig. The adjustable ring on the dial allows you to align the [O] with the hands without affecting the accuracy of the test results.
Note:
In general, loads exceeding the maximum range are applied to machines. After testing the load, the load test machine will gradually deteriorate and get the correct load test value. When using, please do not overload it to maintain the life of the machine.