Feature

●1. Small electrode size, easy to carry. The cavity is made of clear organic glass and is useful for observing the saturation of copper sulfate solutions
●The standard condition for 2 electrode potential, stability, and the potential caramel electrode is 70+3mV, which is consistent with the theoretical value and the potential difference between each other is less than 1 mV
●3 electrodes are not easy to polarize, the potential difference between electrodes is less than 3 mV. Electrode resistance is less than 3K
●4. The utility model has the advantage of a long service life of the electrode, and the electrode cap is connected to the electrode cavity by the screw hole. The utility model can be used for more than 1 year unless the cavity is damaged, and can be used multiple times
●5. Utility model has the advantage of the solid construction of the electrode, corrosion resistance of the joints, proper leakage rate of microporous membranes, no visible fluid flow and can be placed in the pocket


Description

Copper Sulfate Reference Electrode Specifications: Diameter: Approx. 1.2 inches (30 mm), Length: Approx. 5.9 inches (150 mm).
Function Usage
Portable copper sulfate reference electrode is suitable for field use. Mainly used for measuring natural and underground metal pipelines of cathode corrosion protection, stray current. It can also be used as a reference electrode for additional control potential, current cathode corrosion system. Can also be used to measure potential differences in rebar concrete and rebar concrete. Cable Metal Sheath
The electrodes can be used in a variety of soils and fresh water, including sticky areas of soil.
How to use:
1 Insurance industry reference electrode, infuse the copper sulfate particles of more than 2cm of sulfate on the front cover, shake several times to fully dissolve copper particles of sulfate.
2. Soak the gas reference electrode in water and dip it.
3. Insert the end of the reference electrode into the wet soil near the metal structure, adjust the multimeter to the range of the 2V file, connect the reference electrode to the black end of the multimeter.
The red line of 4 multimeter is used to clamp test lines in the pile, read and record data.