Feature

●Product Name: Carbon Fiber Electric Heating Wire
●Insulation: Silicone rubber
●Maximum endurance temperature: 412°F (200°C)
●Heating temperature: Based on the length of use
●Heating conductor: 12K


Description

Technical data:
Product Name: Carbon Fiber Electric Heating Wire
Insulation: Silicone rubber.
Maximum endurance temperature: 412°F (200°C).
Heating temperature: Based on the length of use
Heating conductor: 12K
Leakage current: 0.05 mA/m
Product can bear maximum power: 25W / M
Diameter: 3±0.1MM (Thicker, Safer ;)
Color: Red
Infrared Wavelength: 8UM-18UM
Conductor resistance: 33±10%/m

Package Includes:
1. Buy 100m = 100m cable + 20pcs copper tube + 20pcs sleeve
1.Buy 50m = 50m cable + 10pcs copper tube + 10pcs sleeve
1. Buy 30m = 30m cable + 6pcs copper tube + 6pcs sleeve
1. Buy 20m = 20m cable + 4pcs copper tube + 4pcs sleeve
1. Buy 15m = 15m cable + 4pcs copper tube + 4pcs sleeve
1. Buy 10m = 10m cable + 2pcs copper tube + 2pcs sleeve

How to calculate power?
Voltage x Voltage / Resistance = Power
12K=33 Ohms/m
For example, if you use a 12K carbon fiber cable at 220V, power is as follows:
220V*220Vb/(10m*33)=150W
150w/10m=15w/m
For example, if you use a 12K carbon fiber cable at 220V, power is as follows:
220V*220Vb/(15m*33)=100W
100w/15m=6.66w/m
The longer the length, the smaller the power and the heating temperature is reduced.

What is the power of the cable? What is the heating temperature?
1. The power of the cable is based on the length used. You can calculate power according to the above examples.
2. Power = 5W/m, temperature is about 30~40℃.
Power = 10W/m, temperature is about 40~50℃
Power = 15W/m, temperature is about 50-60℃
Power = 20W/m, temperature is about 60-70℃
Power=25W/m, temperature about 70~90℃ Please note that this is for reference and not accurate due to different test conditions.

Installation Suggestion:
Due to the characteristics of carbon fiber cable, it can not be used for a long For floor heating, it is recommended to use 10 meters per piece and connect all pieces in parallel connections. The distance between cables should be 8-12cm.

Questions & Answers:
Q1: What does it mean to "12K"? What is the difference between 12K and 24K?
A1: "K" means 1000, 12K is 12000. This means that the conductors of 12K carbon fiber heating cables are combined with 12000 carbon fibers, and the resistance is 33 Ohms/m. The conductor of the 24K cable is combined with 24000 carbon fibers, with a resistance of 17 Ω/m.
Q2: What is the difference between rubber jacket and Teflon jacket?
A2: 1.Rubber jacket is more flexible and thick. There will be a little smell, but the smell will disappear after a few days.
2. Teflon jacket is a little harder and thinner than rubber jacket but no smell.