●Automatic Heating: Optional automatic heating function can be used to detect snow and prevent freezing and condensation in high humidity conditions for a long time
●HIGH SENSITIVITY: Unique AC measurement technology prevents the oxidation of the induction plate to ensure long term sensitivity. The sensitivity of the sensor is adjustable for more flexibility
●Strict Temperature Control: In order to prevent peroxidation caused by dry combustion and extend service life, temperature is strictly controlled within 40℃) (default
●Main function: Rain and snow sensor is a qualitative measuring device for measuring whether rain or snow fall outside or in nature. For rain and snow measurements, the response time is less than 0.5S. Applications: Widely used for measuring the presence of rain and snow in the environment, greenhouses, cultivation, architecture, and architecture
●PROTECTION: IP68 protection grade design, can be used outdoors for a long time. Set alarm and reset delay to avoid frequent onsite alarms. Safe, reliable, beautiful and easy to install


Description

Material: Plastic
Weight: Approx. 5.5 oz (153
Size: 89 x 64 x 38 mm
Power Supply: 10-30 V DC
Normal Operating Power: 0.4 W
Storage Environment: -40°C - 80°C
Output signal: 485
Parameter Configuration: Software Settings
Default address: 01
Support function code: 03,06
Maximum heating temperature: 104°F (40°C).
Output relay with load capacity: 250 VAC 1 A, 30 VDC 1 A
Product Model Number: RS YUX N 01 H
Product Type: 485 Modes, Automatic Heating
Wiring Order: VCC) Brown) GND) Black(A) Yellow) B) Blue
Ambient temperature of heating starting: <15°C) default.
Maximum heating temperature: 104°F (40°C) (default)
Operating power when heating: 2.4 W
Power Supply: Positive Power Supply: 10-30 V DC) Brown), Negative Power Supply: Black)
Output: 485 A) Yellow), 485 B Blue.
Why the device may not connect to a PLC or a computer:
1) There are multiple COM ports on the computer and selected ports are incorrect
2) Device with incorrect or duplicate address) Factory default value 1)
3) Baud rate, inspection method, data bit, stop bit error
4) Host polling intervals and standby response time are too short, both should be set to more than 200 ms