Material: Plastic
Weight: Approx. 5.5 oz (153
Size: 89 x 64 x 38 mm
Power Supply: 10-30 V DC
Normal Operating Power: 0.4 W
Storage Environment: -40°C - 80°C
Output signal: 485
Parameter Configuration: Software Settings
Default address: 01
Support function code: 03,06
Maximum heating temperature: 104°F (40°C).
Output relay with load capacity: 250 VAC 1 A, 30 VDC 1 A
Product Model Number: RS YUX N 01 H
Product Type: 485 Modes, Automatic Heating
Wiring Order: VCC) Brown) GND) Black(A) Yellow) B) Blue
Ambient temperature of heating starting: <15°C) default.
Maximum heating temperature: 104°F (40°C) (default)
Operating power when heating: 2.4 W
Power Supply: Positive Power Supply: 10-30 V DC) Brown), Negative Power Supply: Black)
Output: 485 A) Yellow), 485 B Blue.
Why the device may not connect to a PLC or a computer:
1) There are multiple COM ports on the computer and selected ports are incorrect
2) Device with incorrect or duplicate address) Factory default value 1)
3) Baud rate, inspection method, data bit, stop bit error
4) Host polling intervals and standby response time are too short, both should be set to more than 200 ms