Feature

●Wide Range of Use: Can be used for diesel, kerosene, gasoline, etc
●High Definition Display: High resolution display displays both instant flow and cumulative flow
●【Modular Design】Modular design is suitable for use with output modules, sensors, and remote transmitters
●Compact Structure: Compact construction makes it easy to install
●Intuitive Clear: Intuitive clear reading, high reliability, measurement accuracy is ±1%

[Blue LLW-25]




[Red LLW-25]





Description

Description:
This digital turbine flow meter has a modular design high precision compact size with stable performance. Easy to replace and maintain internal components. Suitable for use with output module sensor remote transmitter.

Features:
Modular design makes it suitable for use with output module sensor remote transmitter. Compact construction for easy installation Intuitive clear readable reliability. Measurement accuracy is ±1%. High resolution display displays both instant flow and cumulative flow. Widely used for measuring diesel kerosene gasoline, etc.
Specifications:
Operating Voltage: 2.3-3.3V
Battery Type: 2 x AAALRO3 Batteries
Screw Size: 1" NPT
Repeat: ±0.5%
Measurement accuracy: ±1%
Maximum Working Pressure: 20 BAR.
Flow range: 25-150L/min, 35-250L/min.
Single Count: 0.00-999.9
Total Cumulation: 0-9999
Number of errors: 0.1000-9.999
Operating Temperature: -10°C to +60°C (14°F to 140°F)
Standby time: 1 year
Use: Diesel kerosene gasoline
Color: Red Blue (Optional)
Weight: 12.7 oz (371

Malfunctions and Solutions:
The flow meter is not accurate. 1. Method Field Calibration is not correct. Calibrate again. 2. Meter flow rate is minimum. Increases flow rate 3. The flow meter is blocked by dry liquid. Take out the impeller and clean carefully to make sure the impeller rotates freely. 4. The impeller is wrapped in sealing material Install the meter to remove and make sure the impeller rotates freely 5. It is too close to the impeller. Install correctly 6. Motor or electronic noise too close to environment installation correct. Writing numbers will be lighter or blank. 1. Battery is running out or connected Check Please replace or replace batteries. The flow rate is normal, but the meter cannot be counted. Press the DISPLAY button to activate the meter. 1.1 Incorrect field calibration Calibrate again. 2. Impeller is blocked or damaged. Install the meter to remove and make sure the impeller rotates freely 3. Impeller is wrapped in sealing material Install the meter to remove and make sure the impeller rotates freely Low flow rate and cannot count meters. Press the DISPLAY button to activate the meter. 1.1 The flow meter is blocked by dry liquid. Take out the impeller and clean carefully to ensure that the impeller rotates freely. 2. Meter flow rate is minimum. Increases flow rate Meter cannot be calibrated 1.1 The circuit board is fault. Replacement Circuit Board 2. Button will not be pressed Replacement Circuit Board

Package List:
1 x Turbine Flow Meter
1 x Manual (English language not guaranteed).

Note: The new and old type of this item will be sent randomly, so please do not mind before you place the order.